CamPulse EF

Application Areas
- Air intake for gas turbines, compressors and large engines
- Desert and arctic environments
Filter Element Construction
The CamPulse EF filter elements are used in automatic, self-cleaning air filter systems based on single stage, high efficiency barrier filter sets. Each set consisting of one cylindrical element type CY-2612 and one conical element type CO-2612.
Top and bottom end caps are made of galvanized steel.
Rigid expanded metal inner and outer liners support the media pack and prevent the element from collapsing at extreme, high pressure drop.
The outer expanded metal liner protects the media from damage during handling.
The filter media is securely fixed to the inner and outer liner by beads to prevent movement of the media during pulsing in order to avoid premature wear of the media.
The filter media is water repellent and is corrugated perpendicularly to the pleat direction to ensure even spacing of pleats and prevent them to collapse. Composed of a resin impregnated mixture of cellulose and synthetic fibers, our filter media is available in three different grades: standard cellulosic, blended PolyTech and the ultra high efficiency PolyTech HE media.
PolyTech media is manufactured to Camfil Farr’s specifications and provides improved performance under conditions of high humidity and abundant water.
Mounting gaskets are made of closed cell neoprene or other suitable material permanently glued to the end cap.
Efficiency is tested* in accordance with the ASHRAE Standard 52.1-1992. Test data can be provided on request.
*by an independent test institute
| Model | Dimensions (in.) | Media Area (FT²) | Air Flow / Pressure Drop | Filter Class | Shipping Data (kg) | ||
| Height | Diameter | m³/h/Pa | cfm/"wg | ||||
| CY-2612 | 26.00 | 12.75 | 231.1 | 1062/211 | 625/0.83 | F9 | 7 |
| CO-2612 | 26.00 | 17.52/12.75 | 274.4 | 1261/211 | 745/0.83 | F9 | 9 |


Specifications (CamPulse EF, CY-2612 / CO-2612)
Type: Single stage, high efficiency Pulse filter cartridge
End Caps: Galvanized steel
Liners: Expanded galvanized steel
Media: Resin impregnated mixture of cellulose and synthetic fibers
Separator: Hot melt beads
Seal: Adhesive bonding layer
Gasket: Closed cell neoprene or equivalent
Class EUROVENT 4/9: F9
Recommended final pressure drop: 1000 Pa / 4.0" WG
Recommended air flow per set of cartridges CY-2612/CO-2612: 2500 m³/h /1470cfm
Temperature: 80°C / 176°F max
Degradation pressure: 10kPa / 40" WG
Cartridges are also available with all stainless steel or epoxy coated parts for highly corrosive environments.
All specifications and data are subject to change without prior notice.
Contact us for additional information on:
-
Gas turbine intake filtration
-
Mist elimination
-
Intake & Exhaust silencing
-
Acoustic packages
-
Inlet cooling
-
Filtration upgrades / Retrofits
-
Life cycle projections for your applications